    Product name: SHGV
    Listing Date:2017-08-25

    Type SHGV vacuum on-load tap changer is of combined structure, applicable to SF6 gas insulation regulating transformers, comprising two major parts: diverter switch and tap selector. Tap changer is laid in the transformer gas tank by means of its head flange and the diverter switch is in a separate gas compartment. It can be used at neutral point of star-connection for three-phase; singe-phase for any selectable winding connection; a combination of three units of single-phase for any selectable winding connection and any position voltage regulating.

    Item

    Specification

    SHGV

    1

    Max. rated through-current (A)

    400

    600

    800

    2

    Rated frequency (Hz)

    50 or 60

    3

    Connection

    3-phases Y connection for neutral point only

    Single-phase for any selectable winding connection

    4

    Max. rated step voltage (V)

    4000

    5

    Rated step capacity (kVA)

    1200

    1500

    1600

    6

    Short-circuit

    current test (kA)

    Thermal (3s)

    6

    8

    9.6

    Dynamic (Peak)

    15

    20

    24

    7

    Max. Operating Positions

    27

    8

    Insulation

    to ground

    (kV)

    Highest voltage for

    equipment Um

    72.5

    126

    Rated separate source AC

    withstand voltage (kV/50Hz,1min)

    140

    230

    Rated lightning impulse

    withstand voltage (kV,1.2/50μs)

    350

    550

    9

    Tap selector

    4 grades of B, C, D and DE according to insulation level

    10

    Mechanical life

    Not less than 1,500,000 operations

    11

    Contact life

    Not less than 300,000 operations

    12

    Oil compartm-ent of diverter switch

    Service pressure

    0.03Mpa

    Leakage test

    No leakage under 0.08Mpa for 24 hours

    Over pressure protection

    Bursting cap busts at 300 ± 20%kPa

    Protection relay

    Oil flow speed set at 1.0m/s ±10%

    13

    Motor drive unit

    SHM-D or CMA7

    14

    Oil filter plant

    ZXJY-1 / ZXJY-2 / ZXJY-3 according to requirement (Necessary when max. rated through current is 1000A and above or OLTC used for industrial applications)


    Download / Download 更多>>
    Related Products
    / Case More>>
    2017 - 08 - 01
    Clicks:
    2016 - 07 - 31
    Clicks:
    德甲投注 Copyright © 2005 - 2013 Shanghai Huaming Power Equipment
    犀牛雲提供企業雲服務
    Address: No.977, Tongpu Road, Shanghai, 200333, China 
    Tel: 86 21 5270 8966
    E-mail: export@huaming.com
    郵編:330520
  • <menu id="Ad06y"><small id="pBni0y"></small></menu>
  • <center id="1I5mx"></center><input id="t0Cev"></input>